Blog
SP4402 Specs: Emerson Unidrive SP 37kW/45kW AC Drive Guide

The SP4402 is a three-phase AC drive from the Control Techniques Unidrive SP series, historically marketed under the Emerson brand. It operates with a 380–480V AC supply and has dual motor ratings: 37 kW (60 HP) in Heavy Duty mode and 45 kW (60 HP) in Normal Duty mode. Its corresponding continuous output current ratings are 74 A and 83 A. Designed for industrial motor control, the SP4402 supports open-loop vector, closed-loop vector, and servo operating modes, with additional functionality depending on the selected configuration and options.
SP4402 Technical Specifications
The SP4402 is a Frame Size 4 drive in the 400V Unidrive SP range. The dual-rating capability helps engineers match the drive’s output current and overload capacity to specific motor and load requirements.
| Specification | Details |
|---|---|
| Product model | SP4402 |
| Manufacturer / brand | Control Techniques / Emerson |
| Product series | Unidrive SP |
| Product type | AC variable frequency drive |
| Drive frame size | Frame Size 4 |
| Input voltage | 380–480V AC, ±10% |
| Input phases | Three-phase |
| Input frequency | 50/60 Hz |
| Heavy Duty motor rating | 37 kW / 60 HP |
| Normal Duty motor rating | 45 kW / 60 HP |
| Heavy Duty continuous output current | 74 A |
| Normal Duty continuous output current | 83 A |
| Heavy Duty open-loop peak current | 111 A |
| Heavy Duty closed-loop peak current | 129.5 A |
| Normal Duty peak current | 91 A |
| Motor control modes | Open-loop, closed-loop vector, servo |
| Communication expansion | Optional fieldbus and communication modules |
| Protection rating | IP20 |
| Standard switching frequency | 3 kHz |
| Reference ambient temperature | Maximum 40°C for published standard current ratings |
| Reference installation altitude | 1,000 m |
Source: Control Techniques Unidrive SP User Guide, Issue 12, Tables 2-2 and 2-5. However, engineers must reduce the output current when switching frequency, ambient temperature, or installation altitude exceeds the specified limits.
37kW Heavy Duty vs 45kW Normal Duty: What Is the Difference?
The SP4402 uses a dual-rating system. The selected operating duty determines which continuous current rating and motor power rating apply.
| Parameter | Heavy Duty | Normal Duty |
|---|---|---|
| Motor power at 400V | 37 kW | 45 kW |
| Horsepower | 60 HP | 60 HP |
| Continuous output current | 74 A | 83 A |
| Peak output current | 111 A open-loop / 129.5 A closed-loop | 91 A |
| Typical application | Constant-torque and higher-overload applications | Lower-overload fan and pump applications |
When should you choose Heavy Duty?
Heavy Duty is intended for applications requiring greater short-term overload capability, constant torque, or full torque at low speeds.
Typical examples include:
- Industrial winders and unwinders.
- Hoisting and lifting machinery.
- Material handling equipment with demanding starting loads.
- Machines requiring substantial torque during acceleration.
For SP4402, Heavy Duty provides 74 A continuous output current and a 37 kW motor rating at 400V.
When is Normal Duty more appropriate?
Normal Duty is intended for applications with lower overload requirements, particularly self-ventilated induction motors where full torque at very low speeds is not essential.
Typical examples include:
- Industrial ventilation fans.
- Water circulation pumps.
- Process pumps with relatively stable loading.
- Other variable-torque applications.
In Normal Duty mode, SP4402 provides 83 A continuous output current and a 45 kW motor rating at 400V.
The higher Normal Duty power rating does not mean it is automatically suitable for every 45 kW motor. The motor’s rated current, starting requirements, and load characteristics must still be checked.

Motor Control Modes and Performance
One reason the Unidrive SP platform is used in demanding industrial applications is its range of motor control modes. The SP4402 can be configured for different motor technologies and feedback requirements.
| Control mode | Motor type / feedback | Typical application |
|---|---|---|
| Open-loop vector | Induction motor without encoder feedback | General industrial speed and torque control |
| Closed-loop vector | Induction motor with compatible feedback device | Accurate speed control and low-speed torque |
| Servo | Permanent-magnet brushless motor with feedback | Precision speed and position-related applications |
Open-loop vector control uses motor parameters to improve torque and speed performance without requiring an encoder. By using encoder feedback, closed-loop vector control improves speed accuracy and maintains better motor control, even at very low speeds.
Servo operation is intended for compatible permanent-magnet brushless motors and requires an appropriate feedback arrangement.
The Unidrive SP manual also explains regenerative operation. However, standard SP4402 configurations do not necessarily include all the hardware required for regeneration. Therefore, engineers should check the installed hardware and regeneration setup before selecting four-quadrant operation.
Communication Options and Modular Expansion
The Unidrive SP platform uses a modular architecture. Its expansion options allow the drive to be integrated into different industrial automation systems.
Depending on the installed Solutions Modules, available integration options include:
- PROFIBUS-DP communication.
- DeviceNet communication.
- CANopen communication.
- Ethernet-based communication options.
- Encoder and motor feedback interfaces.
- Additional application and control functions.
These interfaces are not all standard onboard features. The actual communication protocol and feedback capability depend on the installed modules and drive configuration.
The Unidrive SP platform also supports SMARTCARD functionality, allowing engineers to store and transfer drive parameters. This feature simplifies maintenance across multiple drives with similar settings and helps restore configurations after replacement.
Industrial Applications of SP4402
The SP4402’s power range and flexible motor control architecture make it relevant to several industrial applications.
- Metal processing: Speed and torque control in rolling equipment and wire-drawing machinery.
- Plastic machinery: Motor control in extrusion and film-processing equipment.
- Printing and packaging: Coordinated speed control and tension-related applications.
- Multi-axis systems: Applications requiring coordinated motor operation and feedback.
- Industrial retrofits: Evaluation as an AC drive option when replacing older DC drive systems.
For tension control and multi-axis synchronization, the control architecture, feedback devices, and application software are just as important as the drive’s power rating. A suitable configuration must be established for the complete machine.
SP4402 Replacement: What Should Engineers Check?
Replacing an existing SP4402 requires more than finding another drive with a 37 kW or 45 kW rating. The replacement must match the electrical supply, motor current, control mode, feedback configuration, and installation requirements.
Before selecting a replacement, check the following:
- Complete model number: Verify SP4402 and the drive nameplate details.
- Supply voltage: Confirm the 380–480V three-phase supply and its actual operating conditions.
- Operating duty: Establish whether the existing application uses the 74 A Heavy Duty or 83 A Normal Duty rating.
- Motor information: Record rated voltage, current, power, frequency, and speed.
- Control mode: Identify open-loop vector, closed-loop vector, or servo operation.
- Option modules: Record fieldbus, encoder, feedback, and application modules.
- Drive parameters: Back up the original configuration using the appropriate SMARTCARD or commissioning tools.
- Mechanical installation: Check Frame Size 4 dimensions, cooling requirements, cable routing, and enclosure conditions.
The Unidrive SP product family is an older drive platform. When considering an alternative, engineers should compare actual current ratings, overload capability, control functions, feedback options, and machine interface requirements rather than selecting by kilowatt rating alone.
For the exact model, see the Siesource SP4402 Emerson Unidrive SP product page. Related models such as the Emerson inverter drive range can also be reviewed when evaluating alternative drive capacities.

What Should Buyers Confirm Before Ordering?
For industrial maintenance and replacement projects, the full product reference should be confirmed before purchasing. Similar Unidrive SP models may have different voltage ratings, current capacities, and frame sizes.
Prepare the following information when requesting a quotation:
- Complete model reference: SP4402.
- Required quantity.
- Existing drive nameplate photograph.
- Motor power and rated current.
- Heavy Duty or Normal Duty application.
- Installed Solutions Modules and feedback devices.
- Required product condition and destination.
You can contact Siesource Industrial with these details to help identify the required drive configuration.
Frequently Asked Questions
What is the power rating of SP4402?
The SP4402 is rated at 37 kW in Heavy Duty mode and 45 kW in Normal Duty mode at 400V.
What is the output current of the SP4402?
Its continuous output current is 74 A in Heavy Duty mode and 83 A in Normal Duty mode.
What input voltage does SP4402 require?
The SP4402 belongs to the 400V Unidrive SP range and supports a three-phase AC supply of 380–480V, with a specified ±10% voltage tolerance.
Does SP4402 support servo control?
The Unidrive SP platform supports servo operation with compatible permanent-magnet brushless motors and feedback devices. The actual configuration must include the required feedback hardware and setup.
Can SP4402 replace a 45 kW inverter from another brand?
Not automatically. Motor current, overload duty, voltage, control mode, feedback, braking arrangements, and communication interfaces must be checked before selecting a replacement.
Need a Reliable SP4402 AC Drive?
Looking for the Siemens? No — the Control Techniques Emerson Unidrive SP4402 for industrial motor control or equipment replacement? Siesource Industrial can help you identify the correct drive based on your motor ratings and application requirements.
Contact our team with your required quantity, motor specifications, and product requirements to discuss the SP4402.
View SP4402 Product Details | Request a Quote
Conclusion
The SP4402 is a Frame Size 4 Control Techniques Unidrive SP AC drive designed for three-phase 380–480V industrial motor applications. Its dual rating provides 37 kW and 74 A in Heavy Duty mode or 45 kW and 83 A in Normal Duty mode. Its open-loop vector, closed-loop vector, and servo capabilities make it adaptable to different motor control requirements, subject to the installed feedback and expansion hardware.
For purchasing or replacement decisions, the most important checks are the operating duty, motor nameplate current, control configuration, installed option modules, and electrical installation conditions. These details help determine whether an SP4402 is suitable for the existing industrial application.