Blog
Schneider BMENOC0301 Specs: Modicon M580 Ethernet Communication Module Guide

The Schneider Electric BMENOC0301 is a three-port Ethernet communication module for the Modicon M580 automation platform. It supports Modbus TCP and EtherNet/IP communication, remote I/O scanning, SNMP network management, FDR services, RSTP ring topology, and port mirroring. The module connects through an Ethernet + X-bus backplane and uses three RJ45 Ethernet interfaces. Schneider Electric identifies the BMENOC0302 as its recommended replacement, making lifecycle planning and migration compatibility important considerations for existing M580 installations.
BMENOC0301 Technical Specifications
The BMENOC0301 is designed to extend the Ethernet communication capabilities of a Modicon M580 controller. It supports communication with distributed equipment and compatible industrial network devices while maintaining integration with the controller’s rack architecture.
| Specification | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Product family | Modicon M580 |
| Model number | BMENOC0301 |
| Product type | Ethernet communication module |
| Physical Ethernet interfaces | 3 × RJ45 |
| Ethernet standards | 10BASE-T / 100BASE-TX |
| Transmission speed | 10/100 Mbps |
| Supported protocols | Modbus TCP and EtherNet/IP |
| Communication services | I/O Scanner, messaging, SNMP, FDR, RSTP, port mirroring |
| Embedded switch | Multiport Ethernet switch |
| Web server | Basic web server |
| Backplane compatibility | BMEXBP Ethernet + X-bus rack |
| Power supply | Internal power through rack backplane |
| Current consumption | 555 mA at 3.3 V DC |
| Module format | Standard |
| Net weight | Approximately 0.2 kg |
| Operating temperature | 0°C to +60°C |
| Relative humidity | 10–95% |
| Protection rating | IP20 |
| Marking | CE |
Source: Schneider Electric BMENOC0301 official datasheet and the BMENOC03.1 installation and configuration guide.

How Does BMENOC0301 Work in a Modicon M580 System?
The BMENOC0301 provides an Ethernet communication interface between an M580 controller and external industrial devices. It works alongside the main processor rather than replacing its control functions.
Its main responsibilities include:
- EtherNet/IP communication: Supports cyclic I/O scanning and messaging with compatible devices.
- Modbus TCP communication: Exchanges process data with supported Modbus TCP equipment.
- Remote device connectivity: Connects distributed equipment through the M580 Ethernet architecture.
- Network diagnostics: Provides diagnostic and monitoring services for troubleshooting.
- Configuration recovery: Supports FDR services for compatible devices.
Typical network participants include remote I/O equipment, variable frequency drives, HMIs, industrial computers, and other PLCs. Actual device capacity depends on the selected communication services, firmware, processor, and network configuration.
Understanding the Three Ethernet Ports
The BMENOC0301 has three RJ45 Ethernet connectors. However, their functions are not identical.
| Port | Primary function |
|---|---|
| ETH 1 | Service port for engineering and maintenance access |
| ETH 2 | Device network communication and ring topology connection |
| ETH 3 | Device network communication and ring topology connection |
RSTP and network redundancy
The two device-network ports support RSTP ring topology. This allows the module to participate in an Ethernet network with an alternative communication path when a ring link is interrupted.
RSTP does not mean that every connection is automatically redundant. Network topology, switch configuration, and the communication requirements of connected devices must be designed correctly.
Important Ethernet backplane consideration
The BMENOC0301 can communicate with the M580 CPU through the Ethernet backplane. When this connection is enabled, engineers must follow Schneider’s recommended network wiring arrangement.
Do not create an additional external Ethernet connection between the CPU and BMENOC0301 when the backplane connection is enabled. This can create an unintended network loop because the backplane connection is not protected by RSTP in the same way as the device-network ports.
Refer to Schneider’s BMENOC0301 network cabling guidance before modifying an existing M580 Ethernet topology.
Modbus TCP and EtherNet/IP Communication Capacity
The BMENOC0301 supports both Modbus TCP and EtherNet/IP. This allows an M580 system to communicate with different types of industrial Ethernet equipment without requiring every device to use the same protocol.
According to Schneider’s BMENOC03.1 communication documentation, the module supports the following I/O scanning capacities under the specified configuration:
| Communication feature | Published maximum capacity |
|---|---|
| EtherNet/IP scanner devices | 128 devices, shared with Modbus TCP scanner capacity |
| Modbus TCP scanner devices | 128 devices, shared with EtherNet/IP scanner capacity |
| EtherNet/IP input data per device | 505 bytes, excluding header |
| EtherNet/IP output data per device | 509 bytes, excluding header |
| Modbus TCP read registers | 125 registers |
| Modbus TCP write registers | 120 registers |
These figures describe specific communication functions, not a universal number of devices that can operate simultaneously under every application. Scanner resources are shared, and actual network throughput depends on the communication cycle, device configuration, and application workload.
For engineering calculations, consult Schneider’s BMENOC03.1 technical guide rather than treating the maximum device count as a guaranteed performance figure.
BMENOC0301 Firmware Compatibility: Why PV Revision Matters
One important detail when maintaining an existing BMENOC0301 installation is the relationship between hardware product version (PV) and software version (SV), which identifies the module firmware.
Schneider documents a hardware change beginning with PV13. This revision affects the minimum recommended firmware version.
| Hardware product version | Firmware guidance |
|---|---|
| PV12 or earlier | Accepts all documented firmware versions. |
| PV13 or later | Firmware 2.15 or later is recommended. |
Schneider warns that firmware versions earlier than 2.15 on PV13 or later hardware can disable the Ethernet backplane port regardless of its configured parameter.
If an earlier version has been installed, restoring firmware 2.15 or later allows the backplane port to be enabled or disabled again.
This matters when purchasing a replacement module from a different production revision. Matching the model number alone is not sufficient; the PV label and installed firmware must also be checked.
Official reference: Schneider BMENOC0301 firmware compatibility rule.

BMENOC0301 vs BMENOC0302: What Has Changed?
The most important purchasing consideration is that Schneider Electric identifies BMENOC0302 as the recommended replacement for BMENOC0301.
However, the newer module is not simply a cosmetic revision. Schneider describes BMENOC0302 as a performance Ethernet communication module with enhanced communication, diagnostic, and cybersecurity capabilities.
| Feature | BMENOC0301 | BMENOC0302 |
|---|---|---|
| Product family | Modicon M580 | Modicon M580 |
| Communication protocols | Modbus TCP and EtherNet/IP | Modbus TCP and EtherNet/IP |
| Ethernet communication | Three-port architecture | Performance Ethernet communication module |
| Web services | Basic web server | Enhanced diagnostic web pages |
| Network security | Basic documented services | HTTPS, IPsec with IKEv2, SNMPv3 and NTPv4 |
| Network diagnostics | Standard monitoring and diagnostics | Enhanced diagnostic, rack, alarm and program viewers |
| Product lifecycle | Scheduled discontinuation | Recommended replacement |
The BMENOC0302 provides additional features that are relevant to modern automation networks, particularly where network security, diagnostics, and system visibility are important.
Schneider’s official BMENOC0302 product page describes its enhanced web services and cybersecurity capabilities. Its dedicated BMENOC0302 installation and configuration guide should be consulted when planning a migration.
Is BMENOC0302 a Direct Replacement for BMENOC0301?
Schneider officially lists BMENOC0302 as the recommended replacement for BMENOC0301. This is a useful starting point for purchasing decisions, but it does not mean that every existing installation can be upgraded without engineering checks.
Before making the change, evaluate the following areas:
- Rack compatibility: Verify the existing M580 Ethernet + X-bus backplane and supported module position.
- CPU compatibility: Check the installed M580 processor reference and supported system architecture.
- Firmware and software: Review the required module firmware and EcoStruxure Control Expert version.
- Network configuration: Record IP addresses, device connections, scanner configuration, and network topology.
- Cybersecurity settings: Review whether the new security services require changes to network policies and access controls.
- Commissioning: Validate communication, remote I/O, diagnostics, and application behavior after migration.
For an established production line, it may be appropriate to retain BMENOC0301 when maintaining the existing validated configuration. For a planned modernization project, BMENOC0302 deserves evaluation as the designated successor.
BMENOC0301 Product Lifecycle and Purchasing Planning
Schneider Electric’s current US product listing identifies the following lifecycle dates for BMENOC0301:
| Lifecycle milestone | Published date |
|---|---|
| Scheduled end of commercialization | December 1, 2027 |
| End of standard service | December 31, 2035 |
| Recommended replacement | BMENOC0302 |
End of commercialization means the date after which Schneider will no longer accept orders for the reference under the applicable regional product listing. It is not the same as the end of after-sales support.
For existing users, this creates two different purchasing situations:
- Maintenance and spare parts: BMENOC0301 may remain relevant when an existing installation requires the original module to maintain configuration consistency.
- Modernization projects: BMENOC0302 should be evaluated when additional diagnostics, cybersecurity functions, or a longer-term replacement strategy are required.
Lifecycle dates and service arrangements should be checked against the Schneider website for the purchasing region before making procurement commitments.
What Should Buyers Check Before Ordering BMENOC0301?
For a replacement or maintenance purchase, the exact module reference is only the first verification step.
Prepare the following information before requesting a quotation:
- Complete model number: BMENOC0301.
- Hardware product version (PV).
- Installed firmware version (SV).
- Existing M580 CPU and rack reference.
- Network topology and connected device configuration.
- Required quantity and product condition.
- Destination and delivery requirements.
If the project is considering BMENOC0302 instead, provide the existing configuration and migration requirements so that the replacement can be evaluated against the actual installation.
For related M580 components, see the Schneider BMEP583040 M580 processor guide and the Schneider BMEP584040S Safety processor guide. These modules perform different functions from the Ethernet communication module and should be evaluated as separate parts of the M580 architecture.
For product sourcing, browse the Siesource industrial automation catalogue or provide the complete module reference and hardware details through the Siesource contact page.

Frequently Asked Questions
What is Schneider BMENOC0301 used for?
BMENOC0301 is a three-port Ethernet communication module for the Modicon M580 platform. It supports Modbus TCP and EtherNet/IP communication, remote I/O scanning, and industrial network diagnostics.
How many Ethernet ports does BMENOC0301 have?
It has three RJ45 Ethernet ports. One is designated for service functions, while the other two support device-network connections and RSTP ring topology.
Does BMENOC0301 support Modbus TCP and EtherNet/IP simultaneously?
Yes. Schneider documentation specifies support for both Modbus TCP and EtherNet/IP communication services. Actual communication capacity depends on the configured scanner resources and system architecture.
What is the difference between BMENOC0301 and BMENOC0302?
BMENOC0302 is the recommended successor and provides enhanced diagnostics, web services, and cybersecurity features. The exact migration requirements must be checked against the installed M580 system.
What replaces Schneider BMENOC0301?
Schneider Electric identifies BMENOC0302 as the recommended replacement. It should not be assumed to be a universal plug-and-play replacement without checking hardware, firmware, software, and network compatibility.
Conclusion
The Schneider BMENOC0301 is a three-port Ethernet communication module designed for Modicon M580 automation systems. It supports Modbus TCP, EtherNet/IP, RSTP, FDR, SNMP, and remote device communication through an integrated Ethernet interface.
For existing installations, its hardware revision and firmware compatibility are important maintenance considerations. For future replacement planning, Schneider’s recommended successor is BMENOC0302, which introduces enhanced diagnostics and cybersecurity capabilities. The best choice depends on whether the priority is maintaining an existing M580 configuration or upgrading the communication architecture.