Allen Bradley PLC 1734-VTM
Allen Bradley PLC 1734-VTM 原价为:$46.67。当前价格为:$42.78。
Back to products
Allen Bradley PLC 1734-IB8
Allen Bradley PLC 1734-IB8 原价为:$45.25。当前价格为:$41.48。

Allen Bradley PLC 1734-IE4C

原价为:$317.83。当前价格为:$291.35。

Allen‑Bradley 1734 POINT I/O™ – Modular Distributed I/O Platform

Complete POINT I/O portfolio from Allen‑Bradley. Digital I/O (1‑8 points, 24V DC, 120V AC, 220V AC), analog I/O (voltage/current, thermocouple, RTD), safety I/O (POINT Guard, SIL3/Cat.4), specialty modules (counter/encoder, ASCII serial, IO‑Link Master), and communication adapters (EtherNet/IP, ControlNet, DeviceNet, PROFIBUS). Features modular design, removable termination, RIUP (hot‑swap), DeviceLogix™ on configurable modules, and Studio 5000 Logix Designer® integration. Up to 504 channels per network adapter. Horizontal/vertical mounting without derating. Ideal for distributed I/O applications, machine control, process monitoring, and safety circuits. Built for flexible, cost‑effective control system design.

描述

Main Product Series – Function & Application Comparison

I/O TypeDescriptionKey FeaturesTypical Applications
Digital I/O ModulesDiscrete input, output, and relay modules for 24V DC, 120V AC, and 220V AC signals1–8 points per module, configurable filters, field-side diagnostics, sourcing/sinking options, DeviceLogix optional Machine control, conveyor systems, discrete sensor/actuator interfacing
Analog I/O ModulesVoltage (0–10V, ±10V) and current (4–20mA) input/output modules, thermocouple and RTD modules2–8 channels, individually configurable, on-board scaling, selectable filters, over/under-range detection Process control, temperature monitoring, pressure/flow measurement
Specialty ModulesCounter/encoder, SSI absolute encoder, RS-232/RS-485 serial, IO-Link master modulesHigh-speed counting, positional feedback, ASCII communication, IO-Link device connectivity Position control, high-speed counting, serial device integration
Safety I/O Modules (POINT Guard)Safety-rated digital input and output modules for SIL3/Cat.4 applications1–8 points, safety-rated diagnostics, integrated safety circuits, mixed with standard I/O in same system Emergency stop circuits, safety interlock, machine guarding
Communication AdaptersEtherNet/IP, ControlNet, DeviceNet, PROFIBUS network adaptersDual port EtherNet/IP (linear/star/ring), auto-address/baud, RIUP support, DeviceLogix optional Network connectivity, distributed I/O systems, remote control panels
Terminal Bases & Accessories8‑ and 12‑point terminal base units, power supplies, bus extension cablesRemovable screw or spring-clamp terminals, cold-junction compensation, DIN rail mounting I/O module mounting, field wiring termination

Typical Applications & Industries:
✓ Industrial machine control and automation ✓ Packaging and material handling
✓ Process monitoring and control ✓ Safety systems (POINT Guard I/O)
✓ Remote device panels and local control cabinets ✓ OEM equipment integration

Detailed Description – Allen‑Bradley 1734 POINT I/O™ Platform

1. Series Overview – Modular Distributed I/O Platform

The Bulletin 1734 POINT I/O™ family is a modular, distributed I/O platform from Allen‑Bradley, ideal for applications where flexibility and low cost of ownership are key . As part of Rockwell Automation’s Integrated Architecture®, POINT I/O provides comprehensive channel‑level diagnostics and configurable features that make it easy to apply across any automation system .

Key Family Features:

  • ✓ Modular design – Independent selection of I/O, termination style, and network interface, with 1–8 points per module to minimize system cost and size 

  • ✓ Flexible system architecture – Up to 504 channels on a single network interface 

  • ✓ Easier installation and maintenance – Modules slide together for easy installation and removal; removable termination system accelerates commissioning 

  • ✓ Removal and Insertion Under Power (RIUP) – Replace modules while the system is in operation, reducing downtime 

  • ✓ Mix standard and safety I/O – POINT Guard I/O can be used in the same system as standard I/O 

  • ✓ Multiple network connectivity – EtherNet/IP (linear, star, ring), ControlNet, DeviceNet, PROFIBUS 

  • ✓ Horizontal or vertical mounting – No derating required for orientation 

  • ✓ Conformal coating available – Protects against harsh environments 

  • ✓ Auto Device Replacement (ADR) – Reduces downtime by automatically replacing device parameters 

  • ✓ Studio 5000 Logix Designer® integration – Add‑on‑Profiles provide smooth system integration 


2. Digital I/O Modules – Discrete Control

POINT I/O digital modules offer a wide variety of input, output, and relay modules for discrete control applications .

Digital Input Modules:

  • ✓ Voltage options: 24V DC (sinking/sourcing), 120V AC, 220V AC 

  • ✓ Point density: 2, 4, or 8 inputs per module 

  • ✓ Input delay: Programmable filters (0–65 ms) for noise immunity 

  • ✓ Diagnostics: Wire-off and short-circuit detection on select modules 

Digital Output Modules:

  • ✓ Output types: Sourcing (24V DC), relay (AC/DC), and protected outputs with electronic fuse protection 

  • ✓ Point density: 2, 4, or 8 outputs per module 

  • ✓ Output current: Up to 2.0 A per module (1.0 A per channel) 

  • ✓ Diagnostics: Point‑level output fault states, short‑circuit diagnostics on select modules 

Configurable Modules (1734‑8CFGDLX):

  • ✓ Self‑configuring – Each point can be configured as DC input or output 

  • ✓ DeviceLogix™ Smart Component Technology – Embedded logic‑solving capability within the module, enabling autonomous control distribution 

  • ✓ Peer‑enabled operation – Supports “Auto Produce” data creation without a master unit 

Example Models:

  • 1734‑IB8 – 8‑point 24V DC sinking input module

  • 1734‑OB8 – 8‑point 24V DC sourcing output module

  • 1734‑OW4 – 4‑point relay output module (AC/DC)

  • 1734‑IA4 – 4‑point 120V AC input module 

  • 1734‑OA4 – 4‑point 120/220V AC output module 


3. Analog I/O Modules – Process Signal Processing

POINT I/O analog modules provide high‑accuracy signal conversion for process monitoring and control applications .

Analog Input Modules:

  • ✓ Signal types: Voltage (0–10V, ±10V) and current (4–20mA) 

  • ✓ Resolution: Up to 15 bits 

  • ✓ Configurable channels: Individually configurable, on‑board scaling, selectable filters 

  • ✓ Diagnostics: Over‑ and under‑range detection 

Analog Output Modules:

  • ✓ Signal types: Voltage (0–10V, ±10V) and current (4–20mA) 

  • ✓ Resolution: 14 bits (13 + sign) 

  • ✓ Accuracy: 0.1% Full Scale @ 25°C 

Thermal Modules:

  • ✓ Thermocouple (1734‑IT2I) – Direct thermocouple input with cold‑junction compensation 

  • ✓ RTD (1734‑IR2) – Direct RTD input module 

Example Models:

  • 1734‑IE2V – 2‑channel analog voltage input module, ±10V, 15‑bit resolution 

  • 1734‑IE4C – 4‑channel analog current input module

  • 1734‑OE2V – 2‑channel analog voltage output module, ±10V, 14‑bit resolution 

  • 1734‑IR2 – 2‑channel RTD input module 


4. Specialty Modules – Advanced Functionality

POINT I/O includes a range of specialty modules for advanced control and communication requirements .

Counter/Encoder Modules:

  • ✓ 1734‑VHSC – Very high‑speed counter module for pulse counting and encoder feedback

  • ✓ 1734‑IJ – Incremental encoder interface module (24V DC)

  • ✓ 1734‑IK – Incremental encoder interface module (5V DC)

  • ✓ 1734‑SSI – Synchronous Serial Interface absolute encoder module 

Serial Interface Modules:

  • ✓ 1734‑232ASC – RS‑232 ASCII interface module

  • ✓ 1734‑485ASC – RS‑485/422 ASCII interface module 

IO‑Link Master:

  • ✓ 1734‑4IOL – 4‑channel IO‑Link master module, supports connection to IO‑Link enabled devices 

Address Reserve Module:

  • ✓ 1734‑ARM – Address Reserve Module for system redundancy 


5. POINT Guard Safety I/O Modules

POINT Guard I/O provides safety‑rated input/output modules that can be mixed with standard I/O in the same POINT I/O system .

Key Features:

  • ✓ Safety rating: Achieves SIL3, Cat.4, PLe

  • ✓ Point density: 1–8 points per module

  • ✓ Diagnostics: Built‑in safety diagnostics for high‑availability systems

  • ✓ Mixed with standard I/O: Allows standardization regardless of application requirements 

Example Models:

  • 1734‑IB8S – 8‑point safety input module

  • 1734‑OB8S – 8‑point safety output module 


6. Communication Adapters – Network Connectivity

POINT I/O communication adapters provide the network interface for the I/O system .

EtherNet/IP Adapters:

  • ✓ 1734‑AENT – Standard EtherNet/IP adapter 

  • ✓ 1734‑AENTR – Dual‑port EtherNet/IP adapter for ring/linear topology 

Other Network Adapters:

  • ✓ 1734‑ADN(X) – DeviceNet adapter 

  • ✓ 1734‑ACNR – ControlNet adapter with redundancy support 

  • ✓ 1734‑APB – PROFIBUS adapter 

Features:

  • ✓ Linear, star, and ring EtherNet/IP network topologies supported 

  • ✓ Auto‑address, auto‑baud, and power functions compliant with POINTBus backplane 

  • ✓ Removal and Insertion Under Power (RIUP) support 


7. Terminal Bases & Accessories

POINT I/O modules mount on terminal base units that provide field wiring termination and system power connection .

Terminal Base Options:

  • ✓ 1734‑TB / 1734‑TBS – 8‑point terminal base with removable screw or spring terminals 

  • ✓ 1734‑TOP / 1734‑TOPS – One‑piece 8‑point terminal base with screw or spring terminals 

  • ✓ 1734‑TB3 / 1734‑TB3S – 12‑point terminal base with screw or spring terminals

  • ✓ 1734‑TBJC – Terminal base with cold‑junction compensation for thermocouple modules 

Power Supplies:

  • ✓ 1734‑EP24DC – 24V DC power extension module

  • ✓ 1734‑FPD – Field power distribution module 

Other Accessories:

  • ✓ 1734‑CTM – Common terminal module

  • ✓ 1734‑VTM – Voltage terminal module

Selection Guide – Understanding the Naming Convention (1734 POINT I/O™)

Part Number Format: 1734‑[Function][Type][Density][Suffix]

CodeMeaningOptions
1734POINT I/O product family1734
‑IBDigital Input, Sinking (24V DC)IB = Sinking Input
‑IVDigital Input, Sourcing (24V DC)IV = Sourcing Input
‑IADigital Input, AC (120V AC)IA = AC Input 
‑IMDigital Input, AC (220V AC)IM = AC Input 
‑OBDigital Output, Sourcing (24V DC)OB = Sourcing Output
‑OVDigital Output, Sinking (24V DC)OV = Sinking Output
‑OADigital Output, AC (120/220V AC)OA = AC Output 
‑OWDigital Output, RelayOW = Relay Output
‑IEAnalog InputIE = Input, Electrical
‑OEAnalog OutputOE = Output, Electrical
‑IRRTD InputIR = RTD Input
‑ITThermocouple InputIT = Thermocouple Input
‑IJIncremental Encoder (24V DC)IJ = Incremental Encoder
‑IKIncremental Encoder (5V DC)IK = Incremental Encoder
‑VHSCVery High‑Speed CounterVHSC = Very High‑Speed Counter
‑SSISSI Absolute Encoder InterfaceSSI = SSI Interface
‑4IOLIO‑Link Master4IOL = 4‑Channel IO‑Link
‑232ASCRS‑232 ASCII Interface232ASC = RS‑232 ASCII
‑485ASCRS‑485 ASCII Interface485ASC = RS‑485 ASCII

Density Code (Number of Points):

  • 2 = 2 channels

  • 4 = 4 channels

  • 8 = 8 channels

Suffix Codes:

  • D = With diagnostics

  • E = With electronic fuse protection

  • S = Safety‑rated (POINT Guard)

  • DLX = With DeviceLogix™ technology 

Model Decoder Examples:

Model NumberDecoding
1734‑IB8Digital Input (24V DC), 8 points, sinking
1734‑OB8EDigital Output (24V DC), 8 points, sourcing, electronic fuse protection
1734‑OB8SDigital Output, 8 points, safety‑rated (POINT Guard) 
1734‑8CFGDLXConfigurable I/O, 8 points, configurable as input/output, with DeviceLogix 
1734‑IE2VAnalog Input, 2 channels, voltage (0‑10V, ±10V) 
1734‑OE2VAnalog Output, 2 channels, voltage (0‑10V, ±10V) 
1734‑AENTEtherNet/IP communication adapter
用户评价 (0)

评价

目前还没有评价

成为第一个“Allen Bradley PLC 1734-IE4C” 的评价者
Shipping & Delivery

1. Order Processing: Orders are processed within 1-2 business days after payment confirmation. Weekends and holidays are excluded from processing times.
2. Shipping Options & Timelines :
a.Standard Shipping: 3-7 business days (varies by destination).
b.Expedited Shipping: 2-3 business days (additional fees apply).
c.International Shipping: 7-15 business days (customs may affect delivery).
Notes:
For in-stock items, we ship within 5 business days after payment is received.
Out-of-stock or custom products will have timelines confirmed via email after order placement.
3. Tracking Your Order: You’ll receive a tracking number via email once your order ships. Use our Order Status Portal to check real-time updates.
4. Delivery Issues?
Failed deliveries: Contact your local carrier first, then reach out to us.
Wrong/missing items? Email us within 7 days of delivery with order details.
5. Important Notes Customs & Duties: International buyers are responsible for any import fees.
Address accuracy: Double-check your shipping details—we can’t modify orders once processed!

Questions? Visit our FAQs or contact: Info@siesourcecontrol.com