Pepperl+Fuchs Solenoid Driver KFD2-SH-Ex1.T.OP
$193.00 原价为:$193.00。$175.45当前价格为:$175.45。
The Pepperl+Fuchs KFD2 series solenoid drivers are a comprehensive, safe, and reliable solution. Through intrinsic safety isolation barrier technology, they provide a controlled and safe power and signal interface for field actuators in hazardous areas. Their wide model variety, high safety integrity levels, and intelligent diagnostic functions make them an ideal choice for valve control in the process industry. For detailed information on specific models, please refer to the official data sheets.
Key Features & Benefits
The core advantage of the KFD2 series lies in its function as an isolated barrier, which ensures intrinsic safety by effectively isolating the control side from the hazardous field side, preventing dangerous energy from reaching the field. Key features and benefits include:
High Safety: The series meets stringent safety certifications. Most models are rated up to SIL 2 or SIL 3 (according to IEC/EN 61508), making them suitable for applications with the highest safety requirements.
Flexible Channel Configuration: Available in single‑channel and dual‑channel versions, allowing optimal system cost tailoring based on the number of field devices.
Reliable Power Supply: Powered by 24 V DC and compatible with Power Rail or terminal block wiring for easy system integration and cabling.
Intelligent Diagnostics & Maintenance:
Line Fault Transparency (LFT): Transparently transmits field-side line faults (e.g., short circuit, open circuit) to the control system for rapid diagnosis.
Line Fault Detection (LFD): Some models include this active monitoring feature.
Test Pulse Immunity: Reliably handles test pulses from digital output (DO) modules to avoid spurious tripping.
Convenient Settings & Indication:
Parameter configuration via DIP switches on the device – simple and intuitive.
Front‑panel LED indicators provide clear visual status and fault signalling.
Compact & Rugged Design: Housed in a B2‑type enclosure with a width of only 20 mm and mounts on a 35 mm DIN rail, saving valuable cabinet space. Operating temperature range is typically –20 °C to +60 °C.
Main Models & Selection Guide
The KFD2 series includes multiple variants to suit different application needs. The following table compares key representative models:
| Model | Channels | Main Output Parameters | Logic Input | Safety Level (SIL) | Key Characteristics |
|---|---|---|---|---|---|
| KFD2‑SLD‑Ex1.13100 | 1 | 100 mA @ 13 V DC | Yes | SIL 3 | High‑power output; specifically designed for dual‑coil solenoid valves |
| KFD2‑SLD‑Ex2.1045 | 2 | 45 mA @ 10 V DC | Yes | SIL 3 | Supports bus or loop powering; features LFT |
| KFD2‑SL2‑Ex2 | 2 | 45 mA @ 11.7 V DC | Yes, non‑polarised | SIL 2 | Non‑polarised input; includes LFD |
| KFD2‑SL2‑Ex1.LK | 1 | 45 mA @ 11.2 V DC | Yes, non‑polarised | SIL 2 | Fault indication output and LFD capability |
Note: Model KFD2‑SL2‑Ex1.LK is discontinued and has been replaced by the new model KCD2‑SLD‑Ex1.1245.
Technical Specifications Overview (Example: KFD2‑SLD‑Ex1.13100)
Power Supply: Rated voltage
Ur= 19 … 30 V DC (loop‑powered).Input:
Logic signal:
1signal = 15…30 V DC;0signal = 0…5 V DC.Input current: approx. 6 mA @ 24 V DC.
Output:
Internal resistance
Ri: approx. 64 Ω.Current
Ie: typical 100 mA.Voltage
Ue: ≥ 13 V.Current limit
Imax: 105 mA.
Switching Characteristics:
Switching frequency
f: max. 2 Hz.Switch‑on/off delay: 30 ms / 30 ms.
Physical Specifications:
Dimensions (W x H x D): 20 x 119 x 115 mm.
Weight: approx. 200 g.
Typical Applications
Industries with explosive gas or dust atmospheres, such as oil & gas, chemical, and petrochemical.
Process automation systems for remote valve control.
Safety Instrumented Systems (SIS) as the actuating element (e.g., emergency shutdown valves) driver.
Approvals & Standards
The KFD2 series complies with multiple international standards, including:
Explosion protection: ATEX, IECEx, e.g.,
II 3(1)G Ex ec [ia Ga] IIC T4 Gc.Electromagnetic Compatibility (EMC): Complies with EN 61326‑1 and other industrial location standards.
Functional Safety: Complies with IEC/EN 61508, achieving SIL 2 or SIL 3 levels.


1. Order Processing: Orders are processed within 1-2 business days after payment confirmation. Weekends and holidays are excluded from processing times.
2. Shipping Options & Timelines :
a.Standard Shipping: 3-7 business days (varies by destination).
b.Expedited Shipping: 2-3 business days (additional fees apply).
c.International Shipping: 7-15 business days (customs may affect delivery).
Notes:
For in-stock items, we ship within 5 business days after payment is received.
Out-of-stock or custom products will have timelines confirmed via email after order placement.
3. Tracking Your Order: You’ll receive a tracking number via email once your order ships. Use our Order Status Portal to check real-time updates.
4. Delivery Issues?
Failed deliveries: Contact your local carrier first, then reach out to us.
Wrong/missing items? Email us within 7 days of delivery with order details.
5. Important Notes Customs & Duties: International buyers are responsible for any import fees.
Address accuracy: Double-check your shipping details—we can’t modify orders once processed!
Questions? Visit our FAQs or contact: Info@siesourcecontrol.com

评价
目前还没有评价