Blog

Siemens SIRIUS 3RH Series: Contactor Relays, Auxiliary Contacts & Selection Guide

Siemens 3RH series-2

The Siemens 3RH series covers industrial contactor relays and related auxiliary contact accessories used for control signaling, electrical interlocking, and status feedback. Its model families are not interchangeable: 3RH21 and related references identify complete contactor relays, while 3RH19 and 3RH29 commonly identify auxiliary switches that attach to specified contactors. To choose the correct part, first identify whether you need a complete coil-operated relay or an accessory, then check the coil supply, normally open (NO) and normally closed (NC) contact arrangement, terminal type, and compatible base device.

What Does the Siemens 3RH Series Include?

A contactor relay uses an energized coil to change the state of several auxiliary contacts. These contacts can relay control commands, send status signals to a PLC, or create interlocking logic. They are not a substitute for a power contactor selected to switch a motor load.

An auxiliary switch is different: it is an accessory that adds contacts to a compatible contactor or contactor relay. It has no independently operated coil. The distinction matters when ordering a part for a failed panel: a loose auxiliary block will not replace a complete relay, and a relay with the correct number of contacts may still have the wrong coil supply.

Siemens 3RH Model Families Compared

Model familyTypical product typeMain selection question
3RH11 / 3RH21Contactor relays, including selected coupling and special-duty versionsWhich coil voltage, contact arrangement, terminal version, and application design is required?
3RH22 / 3RH23 / 3RH24Special multi-contact or mechanically latched relay variants, depending on referenceDoes the original machine need additional poles, latching, or a particular contact configuration?
3RH61Contactor relay references from a different SIRIUS product generationWhich contactor family and mechanical dimensions does the installed system use?
3RH19 / 3RH29Attachable auxiliary contact blocks and related switching accessoriesWhich exact contactor family and mounting position are supported?
3RH59 / 3RH69Auxiliary contact/accessory referencesWhat is the exact host device and required contact or accessory configuration?

This is a family-level identification aid, not a universal cross-reference. Even within one family, suffixes can change the connection method, contact layout, operating coil, or special application design. Refer to the exact Siemens order number and product data sheet before choosing a replacement.

How to Read NO/NC Contact Arrangements

NO means normally open: the contact is open when the relay is in its normal, unoperated state. NC means normally closed: the contact is closed in that state. On a typical coil-operated relay, energizing the coil changes these contact positions. Which contact state is appropriate depends on the control logic, not on whether one arrangement is generally better.

Siemens uses two-digit contact identification codes in its SIRIUS documentation. In this context, 40 identifies four NO contacts, 31 identifies three NO plus one NC, and 22 identifies two NO plus two NC. Standard terminal designations also help: pairs ending in 3–4 normally identify NO contacts, while pairs ending in 1–2 identify NC contacts. These conventions are useful for understanding drawings, but the exact terminal assignment still must be checked against the selected part.

For example, the Siesource catalogue includes 3RH2911-1GA31 auxiliary contact block and 3RH1921-1XA22-0MA0 auxiliary contact block. These are separate part references; the number of contacts alone does not make their mechanical mounting interchangeable.

Choose the Complete Relay Before Choosing Its Accessories

Check the relay coil supply

A relay coil must match the control voltage and AC or DC supply used by the panel. Two otherwise similar 3RH relays may have different coil requirements. A 24 V DC relay and a higher-voltage AC relay should never be substituted merely because their contact arrangement looks similar. Also check any PLC coupling or special coil-control requirements.

For a concrete catalogue reference, see Siemens 3RH2131-2BB40. The complete voltage, terminal arrangement, and contact ratings must be checked on the original product marking and manufacturer sheet before ordering.

Check switching duty, not just contact count

Auxiliary contacts are commonly used for control circuits. A contact block rated for one switching category cannot automatically be used for a different current, supply type, or inductive load. Look up the applicable AC-15 or DC-13 rating, where relevant, at the actual operating voltage. Do not assume a nominal current figure applies unchanged to every switching duty.

Identify special and multi-pole versions

Siemens’ SIRIUS catalogue identifies 3RH22 as an eight-pole contactor relay family and 3RH24 as a four-pole latched variant. The supplied model list also includes 3RH23 references, whose exact configuration should be confirmed individually rather than inferred from the prefix. The catalogue includes special 3RH21 versions for PLC coupling and railway applications. An existing machine may depend on one of these features even when a standard relay appears physically similar.

3RH19 vs 3RH29: Why Auxiliary Contact Compatibility Matters

Many replacement mistakes occur at the accessory level. Siemens identifies 3RH29 auxiliary switches for specified 3RT2 power contactors and 3RH2 contactor relays. In contrast, 3RH19 products are associated with earlier 3RT1 contactor configurations and applicable 3RH1 devices, depending on the accessory reference.

For example, 3RH2911-2GA04 belongs to the 3RH29 accessory range, whereas 3RH1921-1EA20 belongs to the 3RH19 range. Do not assume that they use the same mounting clip, contact sequence, or compatible host contactor.

The installation position also matters. Some auxiliary switches mount at the front of the contactor, while others mount laterally. Screw-terminal and spring-loaded terminal versions may require different wiring procedures and space allowances. Siemens’ SIRIUS auxiliary switch selection tables provide the basis for checking supported combinations.

Siemens 3RH series-3

Common Uses in Industrial Control Panels

  • Status indication: An auxiliary contact can report a contactor’s operating state to a PLC input, when the circuit and feedback architecture are designed for it.
  • Interlocking: NC contacts can form part of electrical interlocking logic, for example in an appropriately designed reversing circuit.
  • Control signal multiplication: A multi-contact relay can switch several independent control paths using one coil command, within its published contact ratings.
  • Panel maintenance: A compatible auxiliary block can restore a failed feedback contact without replacing other serviceable components, provided the fault has been correctly diagnosed.

For personnel-safety applications, ordinary auxiliary contacts must not be presumed to provide a certified safety function. The complete circuit and any mechanically linked or mirror-contact features must be assessed under the applicable safety design requirements.

Siemens 3RH Replacement and Ordering Checklist

  1. Photograph the complete order number and terminal markings on the installed relay or auxiliary block.
  2. Decide whether the failed item is the complete coil-operated relay or a detachable auxiliary contact.
  3. For a complete relay, check the coil voltage, AC/DC supply, and control-interface requirements.
  4. Check NO/NC contact count, terminal numbering, switching category, and required current.
  5. For accessories, identify the exact host contactor, frame size, product generation, and front or side mounting position.
  6. Compare terminal technology, wiring layout, physical clearance, and installation procedure.
  7. Request confirmation of the part number, condition, quantity, and destination before purchasing; do not infer stock or delivery from a catalogue listing.

Before opening a control panel, a qualified technician should isolate the appropriate supply and follow the site’s electrical safety procedures. A relay that does not operate may have a control-voltage or wiring problem rather than a defective component.

Siemens 3RH Series Product Model Reference List

The following model index follows the Siesource product-link worksheet. Linked items reproduce the URL supplied for that model; a blank-link entry means the worksheet did not identify a product page. This list is intended for part-number navigation, not for claiming interchangeability between models.

3RH2911-1FA223RH2911-2GA043RH2140-2XF40-0LA23RH2911-1GA31
3RH2924-1GP113RH2131-2BB403RH1921-1XA22-0MA03RH2911-1HA11
3RH2122-1AN203RH2911-1HA213RH2911-2HA313RH2140-2BB40
3RH2122-1BF403RH2140-1AP003RH6911-1HA223RH2122-1AK60
3RH2911-1HA133RH1131-1AP003RH2131-1BB403RH6140-1BB40
3RH1921-1FA223RH1921-1EA113RH2911-1HA223RH2911-1HA31
3RH2122-1AF00-8K3RH2131-1AF003RH2140-1AF008K3RH2140-4AR60
3RH1921-1JA113RH1921-1EA203RH2911-1FB223RH2262-1BB40
3RH2122-1FB403RH2122-1BD403RH2244-1AF003RH2122-2BB40
3RH1921-1HA223RH2344-1AF003RH2440-1AF003RH2140-1BB40
3RH2122-2LB40-0LA03RH2262-2BB403RH2911-2HA303RH2131-2AF00
3RH1921-1LA113RH2911-1NF113RH1917-1FA223RH2140-1AF00
3RH2911-1FB113RH2911-2FA403RH2911-1HA023RH6122-1AP00
3RH6131-1AP003RH6131-1BB403RH2422-1BB403RH6140-1AF00
3RH6131-1AF003RH6122-1AF003RH6911-1FA403RH5921-1EA11
3RH5921-1CA103RH5921-1CA013RH6122-1AN203RH1921-1CA10
3RH1921-1DA113RH1911-1FA403RH6921-1DA113RH1921-1CA01
3RH2911-1MA20

The two entries without confirmed product URLs in the supplied worksheet are 3RH1921-1LA11 and 3RH1917-1FA22. Contact the supplier with the exact part number if these references are needed.

Frequently Asked Questions

What is the Siemens 3RH series used for?

The Siemens 3RH series includes contactor relays and related auxiliary contact accessories used in control circuits for signaling, electrical interlocking, and equipment status feedback.

What is the difference between a 3RH contactor relay and a 3RH auxiliary contact block?

A contactor relay is a coil-operated device with its own switching contacts. An auxiliary contact block is an accessory mounted on a compatible contactor or contactor relay to provide additional contacts.

Can a 3RH19 auxiliary contact replace a 3RH29 accessory?

Not without a manufacturer-confirmed cross-reference. Their intended host contactor families, mounting arrangements, and connection details can differ, so buyers must check the exact part numbers and compatible devices.

How do I choose a Siemens 3RH relay with the correct contacts?

Check the coil supply, required NO and NC contacts, switching duty, terminal arrangement, and physical installation. Confirm the final configuration against the Siemens data sheet for the complete order number.

What should I provide when requesting a Siemens 3RH spare part?

Provide the complete order number, a photograph of the device label, the host contactor model if applicable, quantity, condition requirements, and delivery destination.

Conclusion

Choosing the correct Siemens 3RH part starts with a simple distinction: are you replacing a complete contactor relay or an auxiliary contact accessory? The answer determines which electrical ratings, contact arrangements, and mechanical compatibility checks matter. Use the model list to locate the requested reference, then confirm the exact Siemens specifications before installation.

If you need a replacement or cannot identify the matching accessory, contact Siesource Industrial with the existing model number and installation details to request a quotation.

Leave a Reply